Cooling Tower Inspections

Diagnose, Document, and Plan with Precision

 

Our inspections deliver actionable data, risk prioritization, and system-level insights.

 

Ensure Peak Performance with OBR Cooling Tower Inspections

Cooling towers are vital to industrial, commercial, and HVAC systems. Without regular inspections, minor issues can escalate into costly failures, energy inefficiencies, and compliance risks. OBR Cooling Towers offers comprehensive inspections designed to extend equipment lifespan, optimize performance, and prevent downtime.

What’s Included in Our Inspection?

Our team of experts performs an in-depth evaluation of every critical component, providing a detailed assessment with actionable recommendations.

Cooling Tower FRP Structure

Structural Integrity  Check

  • Evaluation of water basins, wood, fiberglass, steel, and concrete for wear, corrosion, or leaks.

  • Detection of material fatigue and structural weaknesses.

Cooling Tower Fan Assembly

Mechanical Component Analysis

  • Driveshafts, gearboxes, fans, and motors assessed for alignment, lubrication, and performance.

  • Belt and bearing condition evaluations to prevent unexpected breakdowns.

Cooling Tower French Nozzle System

Water Distribution System Assessment

  • Inspection of nozzles, piping, and fill media to maximize heat transfer efficiency.

  • Identification of scale buildup, clogging, or water flow inefficiencies.

Cooling Tower OSHA Escape Ladder Swing Gate

OSHA & Safety Compliance Check

  • Ladder access, guardrails, and other safety components reviewed for compliance.

  • Identification of potential risks for maintenance teams.

Inspection - thermal Efficieny testing

Thermal Efficiency Testing

  • Performance measurement to detect energy inefficiencies.

  • Assessment of cooling capacity and heat dissipation effectiveness.

Inspection - Customized reccomendations

Customized Service Recommendations

  • Detailed report with findings, prioritized repair recommendations, and long-term maintenance strategies.

  • Immediate and future repair cost estimates.

How Our Inspection Process Works

01.

Initial Consultation

Discuss your cooling tower’s condition and schedule an inspection.

02.

On-Site Inspection

Our specialists conduct a full structural, mechanical, and thermal analysis.

03.

Comprehensive Reporting

Receive a detailed report with findings and recommendations.

04.

Implementation Plan

Work with OBR on the next steps for maintenance or repairs.

What Happens If You Skip Inspections?

  • Higher Energy Bills

    Inefficient systems increase operational costs.

  • Unexpected Failures

    Small issues become catastrophic problems.

  • Regulatory Non-Compliance

    Safety violations can result in hefty fines.

Displaced Nozzle Splash Plate + Gromment- Prelimary Inspection 11CT-C

Figure 1: Displaced nozzle splash plate and grommet.

Flex Element Signification Wear - Prelimary Inspection 11CT-C

Figure 2: Cell 11F2 flex element significant wear.

Oil Leak - Prelimary Inspection 11CT-C

Figure 3: Cell 11F1 oil line leak.

Pipe Misalignment - Prelimary Inspection 11CT-C

Figure 4: Pipe misalignment in Cell 11F3.

Fill Damage Due to Nozzle Displacement - Prelimary Inspection 17CT-H

Figure 5: Thirteen fill packs exhibit damage as a result of prolonged water loading caused by damaged or displaced nozzles.

Internal Rot 2- Prelimary Inspection 17CT-H

Figure 6: Significant internal rot identified in column.

Internal Rot 3- Prelimary Inspection 17CT-H

Figure 7: Significant internal rot identified in brace.

Inspection - 11CT-C --09

Figure 8: Further significant internal rot in fan deck longitudinal joist support.

Internal Rot 1- Prelimary Inspection 17CT-H

Figure 9: Further significant internal rot in fan deck longitudinal and column.

Internal Rot 4- Prelimary Inspection 17CT-H

Figure 10: Cell 2 failed transverse brace as a result of excessive rot.

Joist Failure for Fill Support 1- Prelimary Inspection 7CT-F

Figure 11: Fill support overview (Cell 7F1). Numerous joist supports failed at the column hardware connection.

Collapsed Fill Support 1- Prelimary Inspection 7CT-F

Figure 12: Collapsed fill supports on the south side of Cell 7F1.

Collapsed Fill Support 2- Prelimary Inspection 7CT-F

Figure 13: Failed fill joist supports.

Collapsing Fill Media 1- Prelimary Inspection 7CT-F

Figure 14: Each top fill pack is fabricated to fit above longitudinal ties. Each fill “lip” is heavily deflected as fill media begins to collapse.

Collapsing Fill Media 2- Prelimary Inspection 7CT-F

Figure 15: Large gap between top and middle 2’ high fill packs.

Heavily Corroded Output Shaft- Prelimary Inspection 7CT-F

Figure 16: Heavily corroded gearbox output shaft.

Significant Curb Cracking - Prelimary Inspection 5CT-D

Figure 17: Concrete curb significant crack on north side of Cell 5F3.

Vertical Turbines Missing Strainers - Prelimary Inspection 7CT-F

Figure 18: Three of the four vertical turbines are absent strainers.

REASONS TO WORK WITH

OBR COOLING TOWERS

With over 30+ years of industry experience, OBR Cooling Towers is trusted by hospitals, universities, data centers, and industrial facilities nationwide. Our inspections provide actionable insights that help prevent costly repairs and extend the life of your equipment.

Expert Engineering Team

Specialized in mechanical, structural, and thermal analysis.

Comprehensive Reporting 

Receive a full diagnostic report with clear, prioritized recommendations.

Fast Response Time 

Nationwide coverage with quick turnaround times.

Proven Customer Success 

Our inspections have helped clients save thousands in repair costs by identifying issues before they escalate.

OBR-Inspection-Brochure_cover

Download Our Cooling Tower Inspections Brochure

Want a quick overview of what’s included in an OBR Cooling Tower Inspection?

Our brochure breaks it down for you—with details on:

  • What we inspect (structural, mechanical, thermal, and safety)
  • The value of early detection and proactive planning
  • Real-world benefits like reduced downtime and budget optimization
  • Why timing inspections before planned outages helps avoid costly surprises

Whether you're planning next year’s shutdown or reviewing your facility's maintenance strategy, this guide is a great place to start.

Schedule Your Professional Cooling Tower Inspection Today!

Contact us today to discuss your inspection needs and receive a detailed assessment.